Arq Bras Cardiol ; 109(1): 14-22, 2017 07.
Artigo em Inglês, Português | MEDLINE | ID: mdl-28678926

RESUMO

Background: Cox-Maze III procedure is one of the surgical techniques used in the surgical treatment of atrial fibrillation (AF). Objectives: To determine late results of Cox-Maze III in terms of maintenance of sinus rhythm, and mortality and stroke rates. Methods: Between January 2006 and January 2013, 93 patients were submitted to the cut-and-sew Cox-Maze III procedure in combination with structural heart disease repair. Heart rhythm was determined by 24-hour Holter monitoring. Procedural success rates were determined by longitudinal methods and recurrence predictors by multivariate Cox regression models. Results: Thirteen patients that obtained hospital discharge alive were excluded due to lost follow-up. The remaining 80 patients were aged 49.9 ± 12 years and 47 (58.7%) of them were female. Involvement of mitral valve and rheumatic heart disease were found in 67 (83.7%) and 63 (78.7%) patients, respectively. Seventy patients (87.5%) had persistent or long-standing persistent AF. Mean follow-up with Holter monitoring was 27.5 months. There were no hospital deaths. Sinus rhythm maintenance rates were 88%, 85.1% and 80.6% at 6 months, 24 months and 36 months, respectively. Predictors of late recurrence of AF were female gender (HR 3.52; 95% CI 1.21-10.25; p = 0.02), coronary artery disease (HR 4.73 95% CI 1.37-16.36; p = 0.01) and greater left atrium diameter (HR 1.05; 95% CI 1.01-1.09; p = 0.02). Actuarial survival was 98.5% at 12, 24 and 48 months and actuarial freedom from stroke was 100%, 100% and 97.5% in the same time frames. Conclusions: The Cox-Maze III procedure, in our experience, is efficacious for sinus rhythm maintenance, with very low late mortality and stroke rates.


Fundamento: A operação de Cox-Maze III é uma das variantes técnicas no tratamento cirúrgico da fibrilação atrial (FA). Objetivos: Estudar os resultados tardios da operação de Cox-Maze III, quanto à eficácia na manutenção de ritmo sinusal e taxas de mortalidade e acidente vascular cerebral (AVC). Métodos: Entre janeiro de 2006 a janeiro de 2013, 93 pacientes foram submetidos a operação de Cox-Maze III por corte e sutura associada a correção de cardiopatias estruturais. Avaliação do ritmo cardíaco ocorreu por Holter 24 horas. Taxas de sucesso da operação foram estudadas por métodos longitudinais e os preditores de recorrência por análise de regressão de Cox multivariada. Resultados: Foram excluídos 13 pacientes sobreviventes ao período intra-hospitalar cujo seguimento tardio não foi possível. Os 80 pacientes restantes tinham idade média de 49,9 ± 12 anos e 47 (58,75%) eram do sexo feminino. Acometimento da valva mitral ocorreu em 67 pacientes (83,7%). Valvopatia reumática ocorreu em 63 (78,7%). Setenta pacientes (87,5%) tinham fibrilação atrial persistente ou persistente de longa duração. O tempo médio de seguimento clínico com avaliação de Holter foi de 27,5 meses. Não houve óbitos intra-hospitalares. As taxas de manutenção de ritmo sinusal foram 88%, 85,1% e 80,6% aos 6 meses, 24 meses e 36 meses, respectivamente. Os preditores de recorrência tardia foram sexo feminino (RR 3,52; IC 95% 1,21-10,25; p = 0,02), doença arterial coronária (RR 4,73; IC 95% 1,37-16,36; p = 0,01) e maior diâmetro de átrio esquerdo (RR 1,05; IC 95% 1,01-1,09; p = 0,02). A sobrevida atuarial aos 12, 24 e 48 meses foi de 98,5% e as taxas atuariais livres de AVC nos mesmos períodos de 100%, 100% e 97,5%. Conclusões: A operação de Cox-Maze III, na nossa experiência, é eficaz na manutenção do ritmo sinusal, com baixíssimos índices de mortalidade e de AVC tardios.


Assuntos
Fibrilação Atrial/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Acidente Vascular Cerebral/etiologia , Fibrilação Atrial/etiologia , Fibrilação Atrial/mortalidade , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Fatores de Risco , Taxa de Sobrevida , Fatores de Tempo , Resultado do Tratamento
3.
Arq. bras. cardiol ; 109(1): 14-22, July 2017. tab
Artigo em Inglês | LILACS | ID: biblio-887900

RESUMO

Abstract Background: Cox-Maze III procedure is one of the surgical techniques used in the surgical treatment of atrial fibrillation (AF). Objectives: To determine late results of Cox-Maze III in terms of maintenance of sinus rhythm, and mortality and stroke rates. Methods: Between January 2006 and January 2013, 93 patients were submitted to the cut-and-sew Cox-Maze III procedure in combination with structural heart disease repair. Heart rhythm was determined by 24-hour Holter monitoring. Procedural success rates were determined by longitudinal methods and recurrence predictors by multivariate Cox regression models. Results: Thirteen patients that obtained hospital discharge alive were excluded due to lost follow-up. The remaining 80 patients were aged 49.9 ± 12 years and 47 (58.7%) of them were female. Involvement of mitral valve and rheumatic heart disease were found in 67 (83.7%) and 63 (78.7%) patients, respectively. Seventy patients (87.5%) had persistent or long-standing persistent AF. Mean follow-up with Holter monitoring was 27.5 months. There were no hospital deaths. Sinus rhythm maintenance rates were 88%, 85.1% and 80.6% at 6 months, 24 months and 36 months, respectively. Predictors of late recurrence of AF were female gender (HR 3.52; 95% CI 1.21-10.25; p = 0.02), coronary artery disease (HR 4.73 95% CI 1.37-16.36; p = 0.01) and greater left atrium diameter (HR 1.05; 95% CI 1.01-1.09; p = 0.02). Actuarial survival was 98.5% at 12, 24 and 48 months and actuarial freedom from stroke was 100%, 100% and 97.5% in the same time frames. Conclusions: The Cox-Maze III procedure, in our experience, is efficacious for sinus rhythm maintenance, with very low late mortality and stroke rates.


Resumo Fundamento: A operação de Cox-Maze III é uma das variantes técnicas no tratamento cirúrgico da fibrilação atrial (FA). Objetivos: Estudar os resultados tardios da operação de Cox-Maze III, quanto à eficácia na manutenção de ritmo sinusal e taxas de mortalidade e acidente vascular cerebral (AVC). Métodos: Entre janeiro de 2006 a janeiro de 2013, 93 pacientes foram submetidos a operação de Cox-Maze III por corte e sutura associada a correção de cardiopatias estruturais. Avaliação do ritmo cardíaco ocorreu por Holter 24 horas. Taxas de sucesso da operação foram estudadas por métodos longitudinais e os preditores de recorrência por análise de regressão de Cox multivariada. Resultados: Foram excluídos 13 pacientes sobreviventes ao período intra-hospitalar cujo seguimento tardio não foi possível. Os 80 pacientes restantes tinham idade média de 49,9 ± 12 anos e 47 (58,75%) eram do sexo feminino. Acometimento da valva mitral ocorreu em 67 pacientes (83,7%). Valvopatia reumática ocorreu em 63 (78,7%). Setenta pacientes (87,5%) tinham fibrilação atrial persistente ou persistente de longa duração. O tempo médio de seguimento clínico com avaliação de Holter foi de 27,5 meses. Não houve óbitos intra-hospitalares. As taxas de manutenção de ritmo sinusal foram 88%, 85,1% e 80,6% aos 6 meses, 24 meses e 36 meses, respectivamente. Os preditores de recorrência tardia foram sexo feminino (RR 3,52; IC 95% 1,21-10,25; p = 0,02), doença arterial coronária (RR 4,73; IC 95% 1,37-16,36; p = 0,01) e maior diâmetro de átrio esquerdo (RR 1,05; IC 95% 1,01-1,09; p = 0,02). A sobrevida atuarial aos 12, 24 e 48 meses foi de 98,5% e as taxas atuariais livres de AVC nos mesmos períodos de 100%, 100% e 97,5%. Conclusões: A operação de Cox-Maze III, na nossa experiência, é eficaz na manutenção do ritmo sinusal, com baixíssimos índices de mortalidade e de AVC tardios.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Fibrilação Atrial/cirurgia , Acidente Vascular Cerebral/etiologia , Procedimentos Cirúrgicos Cardíacos/métodos , Recidiva , Fibrilação Atrial/etiologia , Fibrilação Atrial/mortalidade , Fatores de Tempo , Taxa de Sobrevida , Fatores de Risco , Estudos de Coortes , Resultado do Tratamento
4.
Arq Bras Cardiol ; 94(1): e7-e10, 2010 Jan.
Artigo em Português | MEDLINE | ID: mdl-20414518

RESUMO

This case report describes a patient with persistent atrial fibrillation (AF) submitted to radiofrequency catheter ablation of AF through the pulmonary vein antrum isolation technique, who developed a severe stenosis of the left superior pulmonary vein (LSPV), without presenting any symptoms. The diagnosis of the PV stenosis was made by a routine postprocedure computed tomography scan of the left atrium, and the patient was subsequently submitted to angioplasty with stenting of the LSPV, resulting in the normalization of pulmonary perfusion, as seen by ventilation/perfusion scan made three months after the LSPV angioplasty.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Pneumopatia Veno-Oclusiva/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Cuidados Pós-Operatórios/normas , Pneumopatia Veno-Oclusiva/patologia
5.
Arq. bras. cardiol ; 94(1): e7-e10, jan. 2010. ilus
Artigo em Inglês, Espanhol, Português | LILACS | ID: lil-543876

RESUMO

Neste relato de caso, descrevemos um paciente portador de fibrilação atrial (FA) persistente, submetido à ablação percutânea da FA pela técnica de isolamento extraostial das veias pulmonares, que desenvolveu uma estenose acentuada do óstio da veia pulmonar superior esquerda (VPSE), sem manifestar sintomas, diagnosticada pela angiotomografia de controle das veias pulmonares. O paciente foi submetido à angioplastia com implante de stent na VPSE com sucesso, resultando na normalização da perfusão pulmonar, verificado pela cintilografia pulmonar realizada 3 meses após a angioplastia.


This case report describes a patient with persistent atrial fibrillation (AF) submitted to radiofrequency catheter ablation of AF through the pulmonary vein antrum isolation technique, who developed a severe stenosis of the left superior pulmonary vein (LSPV), without presenting any symptoms. The diagnosis of the PV stenosis was made by a routine postprocedure computed tomography scan of the left atrium, and the patient was subsequently submitted to angioplasty with stenting of the LSPV, resulting in the normalization of pulmonary perfusion, as seen by ventilation/perfusion scan made three months after the LSPV angioplasty.


En este caso clínico, describimos a un paciente portador de fibrilación atrial (FA) persistente, sometido a ablación percutánea de la FA por la técnica de aislamiento extraostial de las venas pulmonares, que desarrolló una estenosis acentuada del ostio de la vena pulmonar superior izquierda (VPSI), sin manifestar síntomas, diagnosticada por la angiotomografía de control de las venas pulmonares. El paciente se sometió a angioplastia con implante de stent en la VPSI con éxito, resultando en la normalización de la perfusión pulmonar, verificado por el centellograma pulmonar realizada 3 meses tras la angioplastia.


Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Pneumopatia Veno-Oclusiva/etiologia , Cuidados Pós-Operatórios/normas , Pneumopatia Veno-Oclusiva/patologia